Description
Features:
- AC coupling function
- Separate generator interface
- Battery inverter work with utilities to intelligently manage the battery and save bills
- Host inverter automatically generated to manage entire system when parallel
- Equipped with built-in circuit breakers, eliminating the need for additional installation
- Enhanced visibility and user experience through a color LCD touch screen interface
-
- Battery for inverter have more Stronger UPS, max. 250A discharging current
- 200A pass through relay to EPS, easy installation
- Plug & Play, seamless switching under 10ms
- Normal 230, 240V, split phase 120/240, 120/208V, 100/200V available
Certifications
The Luxpower 12KW output 18kW Input is ETL & cETL certified and complies with national and international standards for safety and reliability when connected to the grid.
- Outdoor Rating – NEMA 4X / IP65
- Grid connection – IEEE 1547.1:2020;IEEE 1547:2018, Hawaii Rule 14H, California Rule 21 Phase I, II, III
- Safety – UL1741SB Rule 21, RSD NEC 2020:690.12, AFCI NEC 2020:690.11 / UL1699B, GFDI NEC 2020:690.41(B), CSA 22.2.107.1, CSA 22.2.330
- EMC – FCC Part 15 Class B
Model | LUX-18kPV |
Battery Parameters | |
Compatible Battery Type | Lead-acid/Lithium |
Nominal Battery Voltage | 48V |
Battery Voltage Range | 40~60V |
Maximun Charging/Discharging Current | 250A/250A |
Maximun Charging/Discharging Power | 12000W |
Input DC (PV Side)
|
|
Max. DC Input Power for Single MPP | 12000W/7000W/7000 |
Max. PV Input Power | 18000W |
DC Input Voltage Range | 100V~600V |
Nominal DC Input Voltage | 360V |
Full Power MPPT Voltage Range | 230~500V |
Max. DC Input Current | 25A/15A/15A |
MPPT Number/(Strings per MPPT) | 3(2/1/1) |
Output/Inout AC (Grid) | |
Nominal Powe | 12000W |
Nominal AC Voltage | AC 220V Single Phase, 120/240V Split Phase,
120/208V Three Phase |
Operating Voltage Range | 180~270V |
Max. Continuous AC Current | 50A@240V, 50A@208 |
Nominal AC Frequency | 50Hz/60Hz |
UPS Output-with Battery | |
UPS Max. Output Power | 12000W |
UPS Nominal Output Voltage | AC 220V Single Phase, 120/240V Split Phase,
120/208V Three Phase |
UPS Nominal Output Frequency | 120V/240V, 120V/208V |
UPS Nominal Output Current | 50Hz/60H |
Peak Power | 50A@240V, 57.7A@208 |
Switching Time | 14kW 10minutes / 16kW 5minutes / 20kW 500ms
<20ms |
Efficiency | |
MPPT Eifficiency | >=99.9% |
CEC Eifficiency | >=97.5% |
General Data | |
Cooling | FAN |
Communication | RS485/WIFI/CAN |
Weight (kg) | 50KG |
Dimension(mm) | 670×690×240mm |
Display | Color LCD |
Topolog | Transformer-les |
Ambient Temperature Range | -25~60℃ |
Safty Standard | UL1741 |
EMC | IEEE1547, FCC, SDOC |