Frequently Asked Questions

Growatt Q & A

  • Follow the link to your particular model (note, don’t update firmware just because you feel good about it, unless you have a specific problem you are trying to fix)

    https://watts247.az3.infogenixdev.com/manuals/gw/Firmware/ 

    BE SURE YOU HAVE THE CORRECT FIRMWARE FOR THE CORRECT MODEL. WE WILL NOT BE HELD RESPONSIBLE

    Here is a video as an EXAMPLE updating the 6000T, the procedure is similar for other models (make sure you have the correct firmware downloaded)

    Firmware Update 6000T 

  • Secret to the settings 

    https://www.youtube.com/watch?v=oDiva1SJwpc 

  • Normally , setting 10 should be “2 “for 24V models and “4” for 48V models

    the 24P and 48P use the same firmware and control board. this setting is the only thing that differentiates

     1. Press “UP” and “DOWN” at the same time 

      

    2. Input password “820” and enter the setting 10

      

    3. Press “ENTER”, revise battery number to be
    2 pcs (4pcs for 48P) and confirm by pressing “ENTER”
     

      

    4. Exit 

      

    5. Shut down and restart the inverter  

  •  Adjust or calibrate display values 

      

    1. Press “UP” and “DOWN” at the same time 

      

    2. Input password “111” and enter. 

      

    3. Scroll through to the parameter that
    requires calibration. NOTE A prefix is to Add, S Is to subtract the
    “value” e.g 1.1 in the suffix
     

      

    4. Exit 

      

    5. Shut down and restart the inverter  

  •  Hold down the ENTER and Escape buttons
    simultaneously for more than 5 sec.
     

    The unit will reset to factory defaults  

  •  Factory reset procedure for 24P 48P and LVM-ES 

      

    1. Press “UP” and “DOWN” at the same time 

      

    2. At “PAS” screen prompt Input
    password “305”
     

      

    3. Press “ENTER” 3X slowly 

      

    4. Press “ESCAPE” once 

      

    (Remove solar and AC power, turn inverter
    switch off and allow to turn off after 20 to 60 seconds
     

      

    5. Shut down and restart the inverter) 

  • Inverter Fault Codes …Troubleshooting 

    https://watts247.az3.infogenixdev.com/docs/inverter-fault-codes-troubleshooting/ 

MPP Solar Q & A

  • Follow the link to your particular model (note, don’t update firmware just because you feel good about it, unless you have a specific problem you are trying to fix)

    https://watts247.az3.infogenixdev.com/manuals/mpp/Firmware/ 

    BE SURE YOU HAVE THE CORRECT FIRMWARE FOR THE CORRECT MODEL. WE WILL NOT BE HELD RESPONSIBLE

    Here is a video as an EXAMPLE updating the LVX6048WP, the procedure is similar for other models (make sure you have the correct firmware downloaded)

    LVX6048 WP Firmware  

  • Secret to the Settings

    Some setting numbers may vary, but the setting description is similar

    https://www.youtube.com/watch?v=oDiva1SJwpc  

  • The Manual Way.

    take the manual, and each setting will be denoted by “(Default)” , go through and manually set each setting back to factory defaults.

    Using the PC software.

    Watchpower for all Models EXCEPT the Hybrid 2424, and LVX6048WP, and LVX6048

    Solar Power ONLY for models shown above

    software can be downloaded from MPPSOLAR.COM

    there is a tab called “Factory Defaults” or similar click that

Wiring Diagrams/ Breaker Sizing / Panel Configurations

Which Inverter to choose?

  • This is a link to a Google Docs on a comparison sheet of all inverters available

    click here 

General Troubleshooting / Power issues

Videos