Solar Input Power 5,000W
Max Allowed PV Power 3,250W + 3,250W = 6,500W
Max PV Power Delivered to Battery &
AC Outputs
5,000W
Max DC Voltage (Voc) 500V @ 18A, 450V @ 20A
MPPT Voltage Range 150-425V
Starting Voltage 125V
Number of MPPT 2
Max Solar Strings Per MPPT 2
Max DC Current per MPPT (Self Lim-iting)
10A
Max AC Coupled Input (Micro/String Inverters)
9,600W
AC Output Power 5kW On-Grid & Off-Grid
Connections 120/240/208V Split Phase
Continuous AC Power to Grid (On-Grid) 5,000W 20.8A-L (240V)
Continuous AC Power to Load (Off-
Grid)
5,000W 20.8A-L (240V)
Surge AC Power 10sec
Surge AC Power 100ms
16,000VA L-L (240V)
25,000VA L-L(240V)
Fault Current 100ms 104A L-L (240V)
Frequency 60/50Hz
Continuous AC Power with Grid or
Generator
15,120W 63A L-L (240V)
7,560W 63A L-N (120V)
CEC Efficiency 96.5% (Peak 97.5%)
Idle Consumption Typical—No Load 60W
Sell Back Power Modes Limited to Household/Fully
Grid-Tied
Design (DC to AC) Transformerless DC
Response Time (Grid-Tied to Off-Grid) 4ms
Power Factor +/- 0.9 – 1.0
Parallel Stacking No
Battery (Optional) Output Power 5,000W
Type Lead-Acid or Li-Ion
Nominal DC Input 48V
Capacity 50 — 9900Ah
Voltage Range 43.0 — 63.0V
Continuous Battery Charging Output 120A
Charging Curve 3-Stage w/ Equalization
Grid to Batt Charging Efficiency 96.0%
External Temperature Sensor Included
Current Shunt for Accurate % SOC Integrated
External Gen Start Based on Voltage
or %SOC
Integrated
Communication to Lithium Battery CanBus & RS485
Protections & Certifications
Electronics Certified Safety by SGS Labs to NEC
& UL Specs – NEC 690.4B & NEC 705.4/6
Yes
Grid Sell Back — UL1741-2010/2018, IEE-
E1547a-2003/2014, FCC 15 Class B, UL1741SA,
Yes
PV DC Disconnect Switch — NEC 240.15 Integrated
Ground Fault Detection — NEC 690.5 Integrated
PV Rapid Shutdown Control — NEC 690.12 Integrated
PV Arc Fault Detection — NEC 690.11 Integrated
PV Input Lightning Protection Integrated
PV String Input Reverse Polarity Protection Integrated
AC Output Breakers – 63A Integrated
250A Battery Breaker / Disconnect Integrated
Surge Protection DC Type II / AC Type
II
5K-2P-N

UL Model:
“Sol-Ark-5K-48-ST”
Dimensions (H x W x D) 30.0” x 18.3” x
10.0”
Weight 78 lbs
Enclosure NEMA 3R
Ambient Temperature -25-55°C, >45°C
Derating
Installation Style Wall-Mounted
Wi-Fi & LAN Communication Included
Standard Warranty (verified by HALT Testing) 5 Years
General

 

Additional information

Weight 78 lbs
Dimensions 30 × 18 × 10 in